Call Us/Whatsapp Us: +65 8385 9933 | Email: aman@amanengineering.com.sg for inquiry and free quotation

Design of Structural Steelwork for Fire Resistance to SS EN 1993-1-2

Design of Structural Steelwork for Fire Resistance to SS EN 1993-1-2

Key Takeaways Fire design for steelwork requires more than applying a fire rating to a member. The engineer must connect the design fire, material response, structural resistance, protection system, and site documentation into one coherent basis. Define the required fire resistance period and design fire before checking members. Use temperature-dependent steel properties and verified section […]

FEA Applications in PPVC and MET Steel Modules for Singapore Megaprojects

FEA Applications in PPVC and MET Steel Modules for Singapore Megaprojects

Key Takeaways Finite element analysis (FEA) helps modular construction teams test structural behavior before fabrication, lifting, transport, and installation. In Singapore, its value is greatest when it is connected to DfMA decisions, authority requirements, and practical fabrication constraints. FEA links structural design with manufacturing and assembly decisions. PPVC and MET steel modules require different modeling […]

Slope Stabilisation & Soil Nailing: Submission Workflows for Temporary Hillside Excavations

Slope Stabilisation & Soil Nailing: Submission Workflows for Temporary Hillside Excavations

Key Takeaways A defensible hillside excavation submission connects the ground model, temporary works design, authority requirements, and construction controls from the beginning. Define the temporary and permanent works interfaces before design responsibility becomes unclear. Investigate soil, rock, groundwater, drainage, adjacent assets, and existing utilities proportionately to risk. Verify soil nailing against local and global failure […]

Common Reasons BCA Rejects Temporary ERSS Submissions (And How to Avoid Them)

Common Reasons BCA Rejects Temporary ERSS Submissions (And How to Avoid Them)

Key Takeaways Temporary ERSS submissions are commonly returned when the technical evidence, drawings, design assumptions, and authority responses do not form one clear and verifiable package. Confirm that every required form, report, calculation, drawing, and supporting record is included. Base the ERSS design on current site investigation, groundwater, utility, and neighbouring-structure information. Show the design […]

The Annex C & Annex E Workflow: On-Site ERSS Compliance During Execution

The Annex C & Annex E Workflow: On-Site ERSS Compliance During Execution

Key Takeaways ERSS compliance during execution depends on disciplined supervision, clear authority, and records that connect site actions to approved design and monitoring requirements. Annex C controls the construction and inspection workflow for ERSS works. Annex E provides the monitoring, threshold, and response framework. The RE, RTO, and Site Manager need distinct but coordinated responsibilities. […]

Eurocode 7 Application: Sizing Permanent ERSS using SS EN 1997-1 Singapore National Annex

Eurocode 7 Application: Sizing Permanent ERSS using SS EN 1997-1 Singapore National Annex

Key Takeaways Permanent ERSS design in Singapore requires more than selecting a wall section. It depends on a clear design basis, reliable ground and groundwater information, correct Eurocode 7 design approaches, and coordinated construction-stage controls. Define the retaining system, design life, design situations, and movement criteria before sizing members. Build characteristic soil and groundwater parameters […]

Eurocode 7 (SS EN 1997) for Singapore ERSS: Ultimate Limit State (ULS) vs. Serviceability Limit State (SLS)

Eurocode 7 (SS EN 1997) for Singapore ERSS: Ultimate Limit State (ULS) vs. Serviceability Limit State (SLS)

Key Takeaways Eurocode 7 provides the limit-state framework for Singapore ERSS, but a compliant design also depends on local ground conditions, construction stages, and movement control. ULS checks resistance against collapse, instability, hydraulic failure, and structural failure. SLS checks movements, settlement, deformation, and effects on neighbouring assets. Groundwater and soil variability must be reflected in […]

Temporary King Post and Strutting Systems: Structural Detailing for BCA Approval

Temporary King Post and Strutting Systems: Structural Detailing for BCA Approval

Key Takeaways A temporary king post and strutting system is only as reliable as its design basis, connections, construction sequence, and site control. BCA approval depends on a coordinated package that explains both the engineering and how the system will be built. Define the ground, loading, geometry, and construction stages before detailing steel. Check member […]

Temporary Ground Anchors vs. Strutting Systems: Selection Criteria and BCA Approval Constraints

Temporary Ground Anchors vs. Strutting Systems: Selection Criteria and BCA Approval Constraints

Key Takeaways Temporary excavation support should be selected from the ground model, movement limits, land rights, and construction sequence—not from price alone. The Technical Directors, C&S Consultants, Estimators must align the engineering, approval, and commercial decisions early. Anchors preserve internal excavation space but require suitable ground and legal rights beyond the site boundary. Strutting keeps […]

Structural requirements for solar panel installation on Singapore roofs: A professional guide

Structural requirements for solar panel installation on Singapore roofs: A professional guide

Key Takeaways Structural assessments for solar installations must account for existing roof capacity before project initiation. Compliance with the Building and Construction Authority is mandatory for all rooftop photovoltaic systems. Adherence to Eurocodes and Singapore National Annexes ensures mounting systems meet regional safety standards. Proper wind and drainage design is critical to prevent structural failure […]